index024026.jpg index024024.jpg index004003.jpg index005007.jpg
Copyright 1997-2017 Argus International. All rights reserved.
bookmarkwhitespot.jpg
Figure: PC5520 Precleaning System Machine Dimensions
Model Total Exhaust Volume Port Size Blower Power Ducting Diameter
PC5520
PC5530
600CFM
[42.5CMM]
4" [102mm] Diameter
Two Pipes
1/3HP
4" [102mm]
Two Pipe PVC
Exhaust blower and ducting to be supplied by user.
PC5500 Series Precleaning Systems
The PC5500 series precleaning systems were designed to precede Argus PC4000 series Fusing system as well as the Argus HAL5000 series Hot Air Solder Leveling system. The machine is designed to provide a vigorous spray cleaning, fresh water rinse and turbo air dry. The importance of starting a process with a clean surface cannot be stressed enough; this system provides excellent board cleanliness prior to fusing and/or HASL processes. To maintain machine cleanliness all controls are mounted on a NEMA rated control console that may be placed up to 10 feet [3 meters] from the machine.
AVAILABLE OPTIONS
SUMP HEATING & COOLING: Provides the ability to heat precleaning solutions.
Some precleaning solutions are more active when heated; the sump heating option provides excellent control of sump temperature.
ELECTRICAL SERVICE REQUIREMENTS
Circuit Breaker service is 3-phase configuration with a good Ground.
FRESH WATER RINSE REQUIREMENTS
SHIPPING DATA
Air Freight
900 lbs.
[408.3kg]
1300 lbs.
[589.7kg]
Model
Crate Size
Common Carrier
Crated Weight
PC5520
102" x 63" x 65"
[2.6m x 1.6m x 1.7m]
Crating dimensions and weights are approximate and may vary within 10%.
Model 200-240V 50/60Hz 380-415V 50Hz  440-480V 50/60Hz Power
PC5520 Standard 30A 30A 30A 7kVA
PC5530 Standard 50A 30A 30A 10kVA
PC5520 with Sump Heating 50A 30A 30A 11kVA
PC5530 with Sump Heating 70A 50A 50A 16kVA
Connection Fittings
PC5520
PC5530
2 gal [7.57 liters]
per minute
Model
Volume
3/4" NPT Service
PVC
DRAINAGE REQUIREMENTS
Rinse and Tank Drains (Tank Drain Valve is included and is a gravity fed drain)
Connection Fittings each
PC5520
PC5530
2 gal [7.57 liters]
per minute
Model
Volume each
1-1/2" NPT
PVC
EXHAUST SERVICE REQUIREMENTS
1000 lbs.
[453.6kg]
1400 lbs.
[635.1kg]
PC5530
102" x 63" x 65"
[2.6m x 1.6m x 1.7m]
Figure: PC5530 Precleaning System Machine Dimensions
index001011.jpg arguslogo.gif index001009.jpg index001007.jpg index001013.jpg index001005.jpg index001003.jpg index001001.jpg
Home | Products | Distributors | Topics | LPISM FAQ | About Us | Contact Us | Terms of Use | Site Map